NF-06D metal Anti-static Floor material is a special material prepared from patented product NFJ metal aggregate. Lay on the surface of general concrete. Using new construction technology and synchronous construction with the surface of concrete, to make this kind of material form a whole with the concrete, become the Anti-static Floor with special wear-resisting, impact-resistance. It has been treated with double-chapter anti-rust and has the characteristics of corrosion prevention, anti-static and wear-resistance.

Product Description

NF-06D metal Anti-static Floor material is a special material prepared from patented product NFJ metal aggregate. Lay on the surface of general concrete. Using new construction technology and synchronous construction with the surface of concrete, to make this kind of material form a whole with the concrete, become the Anti-static Floor with special wear-resisting, impact-resistance. It has been treated with double-chapter anti-rust and has the characteristics of corrosion prevention, anti-static and wear-resistance.

Application Scope

Places with high electrostatic sensitivity.

Places requiring special wear-resisting and impact-resisting performance.

places with oil resistance and permeability resistance.

Advantages And Features

The floor is excellent in hardness and toughness.

The floor can meet the requirements from smoothness to skid resistance.

The floor has antistatic function.

The floor has excellent performance on anti-seepage, anti-corrosion and salt-alkali resistance.

The renovation process of the old ground is simple and the construction period is short.

Note: Metal content can be detected by magnet adsorption; Rust resistance test can be soaked in 5% NACL solution.

ItemIndex
Anti-static performanceSurface resistance of test piece:5 x 104~1 x 108Ω
Fireproof gradeGrade A1
Abrasive resistance0.012g/cm2 (gearing method)
Compressive strength (28D)116.1MPa
Rupture strength (28D)>18.5MPa (not broken)
Tensile strength3.9MPa
Impact performance (28D)18MPa
Dry shrinkage value-0.751 x 10-3 (210d)
Hardness (Mohs)8
Rust resistanceResistant NaCL, NaOH and other medium
Green and environmental protection floorWithout harmful radioactivity, harmful volatility and pollution
High temperature resistance+200℃
Freezing resistance

-40℃ (the test piece is flawless and has no loss corner defect even after frozen

 and molten 25 times)(the strength loss rate is -7.3%) (-40℃)

Radon concentration ≤100Bq/m3Maximum value: 22.2
Air cleanlinessLevel 100,000
Slippery resistance gradeAd